China Suppliers Factory EP10202 Thick Paste Aluminum Powder Epoxy Marine Antirust Paint for Ship Bottom
- ✓ Good corrosion resistance to seawater
- ✓ Cathodic protection function
- ✓ Can be applied at low temperatures
- ✓ Good chemical resistance
- ✓ Can cure in humid environments
| Project | Data | ||||
| Density (Kg/L) | 1.2 | ||||
| Color | Aluminium Powder | ||||
| Solid percentage by volume % | 60 ± 2 | ||||
| Reference dry film thickness (μm) | 100 | ||||
| Theoretical coating rate (㎡/L) | 6 | ||||
| Flash point | 30°C [86°F] | ||||
| Volatile matter (g/L) | 340 | ||||
| Gloss | Matte | ||||
| Drying time | 10℃ | 20℃ | 30℃ | ||
| Dry to touch | 90 mins | 45 mins | 35 mins | ||
| Actual drying | 24 hrs | 10 hrs | 8 hrs | ||
| Coating interval | 10℃ | 20℃ | 30℃ | ||
| min | 8 hrs | 6 hrs | 4 hrs | ||
| max | 15 days | 8 days | 5 days | ||
| Potlife | 10℃ | 20℃ | 30℃ | ||
| 12 hrs | 8 hrs | 6 hrs | |||
| Mixing ratio | Base : Hardener (2.5 : 1 by volume) | ||||
| Storage period | 24 months at 25°C | ||||
Method: Airless spraying
Nozzle pressure: 14 MPa – 21 MPa
Nozzle hole diameter: 0.6 mm – 0.8 mm
If applying by brush or roller, additional coats will be required to achieve the specified dry film thickness. Spray data is for reference only and may be adjusted. Pressure is applicable at a material temperature of 20°C [68°F]. Brush and roller application is only suitable for line marking and small repair areas.
During application and curing, the substrate surface temperature must be above 5°C [41°F].
To avoid condensation, the substrate temperature during application must be at least 3°C [5°F] above the dew point, clean and dry.
Relative humidity: The relative humidity during construction and curing must be less than 85%.
Remove oil, grease and other contaminants with a suitable cleaning agent.
High-pressure water cleaning removes salt, detergents and other contaminants.
Surface blasted to Sa 2½ (ISO 8501-1) / SP 10 (SSPC).
Small areas can be cleaned by hand or with power tools as an alternative to sandblasting.
Flash rust should not exceed FR L (ISO 8501-4).
The substrate surface should be Medium (G) (ISO 8503-2).