Leave Your Message

China Factory Suppliers: EP10405 Thick-Film Epoxy Anti-Corrosion Paint for Ship Bottoms - Iron Red Primer

Introducing our high-performance marine two-component epoxy iron red primer, specially designed for optimal corrosion protection. Manufactured in China, this primer features iron oxide red, which enables direct chemical passivation on steel surfaces. Enhanced with flake fillers, it forms a robust physical barrier that effectively prevents water vapor and oxygen penetration. Ideal for metal structures above the water surface, this primer is the perfect solution for applications that require long-lasting protection against corrosion. Trust our factory to provide reliable products that meet your high standards for durability and quality. Choose our epoxy primer for seamless protection in challenging marine environments

    🛡️ Product Characteristics
    The paint has good corrosion resistance to seawater and shielding properties against chloride ions.
    ✅ Recommendations
    Used for surface corrosion protection of metal and cement at sea and underwater.
    📊 Product Parameters
    Project Data
    Density (Kg/L) 1.45
    Color Iron Red
    Solid percentage by volume % 72 ± 2
    Reference dry film thickness (μm) 125
    Theoretical coating rate (㎡/L) 5.8
    Flash point 30°C [86°F]
    Volatile matter (g/L) 225
    Gloss Matte
    Drying time 10℃ 20℃ 30℃
    Dry to touch 180 mins 120 mins 90 mins
    Actual drying 24 hrs 10 hrs 8 hrs
    Coating interval 10℃ 20℃ 30℃
    Min 8 hrs 6 hrs 4 hrs
    Max 15 Days 8 Days 5 Days
    Potlife 10℃ 20℃ 30℃
    6 hrs 4.5 hrs 4 hrs
    Mixing ratio Base : Hardener (4:1 by volume)
    Storage period 24 months @ 25°C
    🔧 Application
    Construction Method
    Airless spraying
    Nozzle pressure: 14 MPa – 21 MPa
    Nozzle hole diameter: 0.6 mm – 0.8 mm
    If applying by brush or roller, additional coats will be required to achieve the specified dry film thickness. Spray data is for reference only and may be adjusted. Pressure is applicable to material temperatures of 20°C [68°F]. Brush and roller application is only suitable for line marking and small area touch-ups.
    Construction Conditions
    During construction and curing, the surface temperature of the substrate must be above 5°C [41°F].
    To avoid condensation, the substrate temperature during construction should be at least 3°C [5°F] higher than the dew point, clean and dry.
    Relative humidity: The relative humidity during construction and curing must be less than 85%.
    Surface Treatment
    Remove oil, grease and other contaminants with a suitable cleaning agent.
    High-pressure water cleaning removes salt, detergents and other contaminants.
    Surface blasted to Sa 2½ (ISO 8501-1) / SP 10 (SSPC).
    Remove dust, sand and loose materials.
    Surface blasted to PSa 2½ (ISO 8501-2) / SP 10 (SSPC).
    High pressure water is sprayed onto Wa 2½ (ISO 8501-4).
    Small areas can be cleaned by hand or electric tools instead of sandblasting.
    The degree of flash rust is not higher than FR L (ISO 8501-4).
    The surface of the substrate reaches Medium (G) (ISO 8503-2).
    ⚠️ Disclaimer
    ⚠️ The information provided in this manual is the most comprehensive and correct information we have at present. Since the conditions of product use are beyond our control, the information here does not contain any guarantee, that is, we are only responsible to the buyer for the product selection. Due to the continuous development of our company's products and production processes, all information here is subject to our confirmation.
    ❓ Frequently Asked Questions
    Q What surfaces is this paint suitable for?
    A This paint is suitable for the surface corrosion protection of metal and cement structures used at sea and underwater environments.
    Q What is the recommended application method for this coating?
    A Airless spraying is the recommended method, using a nozzle pressure of 14–21 MPa and a nozzle hole diameter of 0.6–0.8 mm. Brush or roller application is only suitable for small touch-up areas.
    Q What are the required surface preparation standards before applying the paint?
    A The surface should be blasted to Sa 2½ (ISO 8501-1) / SP 10 (SSPC), and flash rust should not exceed FR L (ISO 8501-4). All oil, grease, salt and loose materials must be removed prior to application.
    Q What environmental conditions are required during application?
    A The substrate temperature must be above 5°C [41°F], at least 3°C above the dew point, and relative humidity must be below 85% during both application and curing.
    Q What is the mixing ratio and pot life of this product?
    A The mixing ratio is Base : Hardener = 4:1 by volume. The pot life ranges from 4 hours at 30°C to 6 hours at 10°C after mixing.
    Q How long can this product be stored, and what is its dry film thickness?
    A The storage period is 24 months at 25°C. The reference dry film thickness is 125 μm, with a theoretical coating rate of 5.8 ㎡/L.

    Leave Your Message