Leave Your Message

China Factory Suppliers EP10405 Thick-Film Epoxy Anti-Corrosion Paint for Ship Bottoms - Iron Red Primer

Introducing our marine two-component epoxy iron red primer, proudly manufactured in China. This high-quality primer features iron oxide red, which chemically passivates directly on steel surfaces, providing exceptional corrosion protection. By incorporating advanced flake fillers, it creates a robust physical barrier that effectively blocks water vapor and oxygen. Ideal for metal structures above the waterline, this product is perfect for suppliers seeking reliable solutions for long-lasting durability. Trust our factory to deliver top-notch protective coatings that stand up to harsh marine environments

    Product Characteristics
    The paint has good corrosion resistance to seawater and shielding properties against chloride ions.
    Recommendations
    Used for surface corrosion protection of metal and cement at sea and underwater.
    Product Parameters
    Project Data
    Density (Kg/L) 1.45
    Color iron red
    Solid percentage by volume % 72± 2
    Reference dry film thickness (μm) 125
    Theoretical coating rate (㎡/L) 5.8
    Flash point 30°С [86°F]
    Volatile matter (g/L) 225
    Gloss Matte
    Drying time 10℃ 20℃ 30℃
    Dry to touch 180mins 120mins 90mins
    Actual drying 24hrs 10hrs 8hrs
    Coating interval 10℃ 20℃ 30℃
    min 8hrs 6hrs 4hrs
    max 15Days 8Days 5Days
    Potlife 10℃ 20℃ 30℃
    6hrs 4.5hrs 4hrs
    Mixing ratio Base: hardener (4:1 by volume)
    Storage period 24months 25°C
    Application
    Construction Method
    • Method: Airless spraying
    • Nozzle pressure: 14 MPa -21 MPa
    • Nozzle hole diameter: 0.6mm-0.8mm
    • If applying by brush or roller, additional coats will be required to achieve the specified dry film thickness. Spray data is for reference only and may be adjusted. Pressure is applicable to material temperatures of 20°C [68°F]. Brush and roller application is only suitable for line marking and small area touch-ups.
    Construction Conditions
    • During construction and curing, the surface temperature of the substrate must be above 5 ° C [41 ° F].
    • To avoid condensation, the substrate temperature during construction should be at least 3 ° C [5 ° F] higher than the dew point, clean and dry.
    • Relative humidity: The relative humidity during construction and curing must be less than 85%.
    Surface Treatment
    • Remove oil, grease and other contaminants with a suitable cleaning agent.
    • High-pressure water cleaning removes salt, detergents and other contaminants.
    • Surface blasted to Sa 2½ (ISO 8501-1) / SP 10 (SSPC).
    • Remove dust, sand and loose materials.
    • Surface blasted to PSa 2½ (ISO 8501-2) / SP 10(SSPC).
    • High pressure water is sprayed onto Wa 2 1/2 (ISO 8501-4).
    • Small areas can be cleaned by hand or electric tools instead of sandblasting.
    • The degree of flash rust is not higher than FR L (ISO 8501-4).
    • The surface of the substrate reaches Medium (G) (ISO 8503-2).
    Disclaimer
    The information provided in this manual is the most comprehensive and correct information we have at present. Since the conditions of product use are beyond our control, the information here does not contain any guarantee, that is, we are only responsible to the buyer for the product selection. Due to the continuous development of our company's products and production processes, all information here is subject to our confirmation.
    Frequently Asked Questions (FAQ)
    What are the primary protective properties of this paint?
    The paint offers excellent corrosion resistance to seawater and provides high-performance shielding properties specifically against chloride ions.
    Where is this product recommended for application?
    It is highly recommended for the surface corrosion protection of both metal and cement structures located at sea or in underwater environments.
    What is the mixing ratio and storage period for this product?
    The mixing ratio is Base: hardener = 4:1 by volume. The product has a storage period of 24 months when kept at 25°C.
    Can this paint be applied using a brush or roller?
    Yes, but brush and roller applications are only suitable for line marking and small area touch-ups. Additional coats will be required when using these methods to achieve the specified dry film thickness.
    What environmental conditions are required during application?
    The substrate temperature must be above 5°C [41°F] and at least 3°C [5°F] higher than the dew point. The relative humidity during both construction and curing must be less than 85%.
    What is the recommended surface preparation?
    Remove oil, grease, salt, and contaminants using suitable agents and high-pressure water cleaning. Blast the surface to Sa 2½ (ISO 8501-1) / SP 10 (SSPC) or PSa 2½ (ISO 8501-2) / SP 10 (SSPC), and ensure all dust, sand, and loose materials are completely removed.

    Leave Your Message